Faster measurement with the new CPU:- 5Y balances feature Dual Core 2 x 1 GB processor which delivers noticeable performance improvements including faster operation and shorter stabilization time retaining high repeatability values.

Repeatability and USP Regulations:-
16 GB RAM – more data management possibilities:- 16 GB RAM offers possibility of recording data in a form of complex reports. Time and statistic data diagrams on series of weighments are another useful option.

SPECIFICATION
MODEL No. MYA 2.4Y MYA 5Y
Maximum Capacity [Max] 2.1 g 5.1 g
Minimum load 100 µg 100 µg
Readability [d] 1 µg 1 µg
Tare range -2.1 g -5.1 g
Standard repeatability [5% Max] 0.41 µg 0.41 µg
Standard repeatability [Max] 1 µg 1.6 µg
Standard minimum weight (USP) 0.82 mg 1.2 mg
Standard minimum weight (U=1%, k=2) 0.082 mg 0.12 mg
Permissible repeatability [5% Max] 0.8 µg 2.4 µg
Permissible repeatability [Max] 1.5 µg 2.4 µg
Linearity ±3 µg ±5 µg
Eccentric load deviation 3 µg 5 µg
Stabilization time max 8s max 8s
Adjustment (Calibration) internal (automatic) internal (automatic)
OIML Class I I
Display 5.7” resistive colour touchscreen 5.7” resistive colour touchscreen
Communication interface 2×RS232, 2×USB-A, Ethernet, 4 IN / 4 OUT (digital), Wi-Fi® 2×RS232, 2×USB-A, Ethernet, 4 IN / 4 OUT (digital), Wi-Fi®
Power supply 100 ~ 240 V AC 50 / 60 Hz 100 ~ 240 V AC 50 / 60 Hz
Power consumption max. 10 W 10 W
Operating temperature +10 ~ +40 °C +10 ~ +40 °C
Operating temperature change rate ±0.3°C/1h (±1°C/8h) ±0.3°C/1h (±1°C/8h)
Relative humidity 40% ~ 80% 40% ~ 80%
Relative humidity change rate ±1%h (±4%/8h) ±1%h (±4%/8h)
Weighing chamber dimensions ⌀90×90 mm ⌀90×90 mm
Weighing pan dimensions ⌀16 mm ⌀26 mm
Packaging dimensions 660×660×455 mm 660×660×455 mm
Net Weight 9.1 kg 9.1 kg
Gross Weight 16.6 kg 16.6 kg
SPECIFICATION
MODEL No. MYA 11.4Y MYA 21.4Y
Maximum Capacity [Max] 11 g 21 g
Minimum load 100 µg 100 µg
Readability [d] 1 µg 1 µg
Tare range -11 g -21 g
Standard repeatability [5% Max] 0.9 µg 1 µg
Standard repeatability [Max] 2.5 µg 3 µg
Standard minimum weight (USP) 1.8 mg 2 mg
Standard minimum weight (U=1%, k=2) 0.18 mg 0.2 mg
Permissible repeatability [5% Max] 1.6 µg 1.6 µg
Permissible repeatability [Max] 3.5 µg 4 µg
Linearity ±6 µg ±7 µg
Eccentric load deviation 6 µg 7 µg
Stabilization time max 10s max 10s
Adjustment (Calibration) internal (automatic) internal (automatic)
OIML Class I I