Description
Your all-in-one solution for multi-parameter research work in the lab! The new PC 2700 is accurate, reliable and intuitive with user-friendly functions. Meter comes with a multi-data screen that includes Temperature, electrode status, calibration points, date and time along with your desired measurement parameter. PC 2700 measures pH, ORP, ION, Conductivity, TDS, Salinity, or Resistivity!
Features:
1.Choose auto-calibration with preset values for quick easy calibration, or manual multi-point calibration for greater accuracy
2.Easy standardization with auto-standardization feature – detect the exact cell constant value of your electrodes with the press of a button
3.Up to 6-point calibration with auto-buffer recognition
4.Includes high performance 4-cell Conductivity probe
5.Quick, easy electrode diagnosis with the effective cell constants display
6.Non-volatile memory holds up to 500 data points – time and date-stamped for GLP compliance
7.Bi-directional RS232 for easy data transfer to computer
| SPECIFICATION | |
|---|---|
| Parameter | Thermo Eutech Multiparameter |
| Model | PC-2700 |
| pH Range | |
| pH Range | -2.000 ~ 20.000 pH |
| Resolution | 0.001, 0.01, 0.1 pH, Selectable |
| Accuracy | ±0.002 pH |
| Calibration Points | Up to 5 points |
| pH Buffer Option |
USA (pH 1.68, 4.01, 7.00, 10.01, 12.45), NIST (pH 1.68, 4.01, 6.86, 9.18, 12.45), DIN (pH 1.09, 4.65, 6.79, 9.23, 12.75) |
| ORP | |
| ORP (mV) Range / Calibration | 0 ~ ±1999.9 mV / 1 point |
| Resolution | 0.1 / 1 mV, Selectable |
| Accuracy | ±0.2 mV |
| Measuring Mode | Absolute mV or Relative mV |
| Conductivity | |
| Conductivity Range | 0 ~ 200 mS/cm |
| Resolution | 0.01 / 0.1 / 1 |
| Accuracy | ±0.5% Full Scale |
| Cell Constant | 0.1 / 1 / 10 / User defined |
| Temperature Coefficient | 0.0 ~ 10.0% per °C |
| Calibration Solutions | 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm |
| Compensation Modes | Linear or Pure Water |
| TDS | |
| TDS Range | 0 ~ 10 ppt (Max. 200 ppt, depending on factor setting) |
| Resolution | 0.01 / 0.1 / 1 |
| Accuracy | ±1% Full Scale |
| TDS Factor | 0.0 ~ 1.0 |
| Salinity | |
| Salinity Range | 0 ~ 80 ppt |
| Resolution | 0.01 / 0.1 / 1 |
| Accuracy | ±1% Full Scale |
| Resistivity | |
| Resistivity Range | 2.000 Ω to 20.0 MΩ |
| Resolution | 0.01 / 0.1 Ω ; 0.001 / 0.1 kΩ ; 0.01 MΩ |
| Accuracy | ±1% Full Scale |
| Temperature | |
| Temperature Range | 0.0 to 100.0 °C / 32.0 to 212.0 °F |
| Temperature Compensation | 0.1 °C / 0.1 °F |
| Temperature Accuracy | ±0.3 °C / ±0.5 °F |
| Coefficient (Per °C) | Linear & Pure ; 0.000 to 10.000 % |
| Normalization | 15.0 to 30.0 °C / 59.0 to 86.0 °F |
| Compensation | ATC / MTC |